DESAIN KOLAM PEREDAM ENERGI BENDUNG PLAOSAN KABUPATEN SEMARANG

ERIC, AFRIDA (2022) DESAIN KOLAM PEREDAM ENERGI BENDUNG PLAOSAN KABUPATEN SEMARANG. Masters thesis, UNDARIS.

[img] Text (tugas akhir bentuk softcopy pdf)
ERIC AFRIDA FT 2022.pdf - Submitted Version
Restricted to Registered users only

Download (3MB) | Request a copy

Abstract

DESAIN KOLAM PEREDAM ENERGI BENDUNG PLAOSAN KABUPATEN SEMARANG Program Studi Teknik Sipil, Fakultas Teknik, Universitas Undaris Jalan Tentara Pelajar No.13 Ungaran, Kabupaten Semarang. 50514, ABSTRAK Aspek hidraulik pada bendung merupakan salah satu faktor yang sangat penting dalam perencanaan kolam peredam energi. Sisa energi di hilir kolam peredam energi diharapkan menjadi minimal sehingga gerusan dasar sungai tidak membahayakan. Saat ini, pada Bendung Plaosan belum terdapat struktur kolam peredam energi. Oleh karena itu perlu direkomendasikan desain kolam untuk mengantisipasi gerusan. Analisis yang dilakukan meliputi analisa hidrologi antara lain menghitung curah hujan rencana tahunan, debit banjir rencana (Q) menggunakan metode Haspers, dan menghitung bilangan Froude (Fr) untuk menentukan type kolam yang sesuai. Kemudian didapat rekomendasi desain tipe kolam peredam energi serta dilakukan pula analisa stablilitas yang bekerja pada bangunan. Dari hasil perhitungan curah hujan rencana diperoleh rencana curah hujan kala ulang 50 tahun sebasar 108,68 mm. Debit rencana 50 tahun sebesar 186,06 m 3 /det, bilangan froude = 4. Adapun tipe kolam peredam energi yang sesuai adalah USBR Tipe IV. Kolam direncakan mempunyai panjang L 17 m, dengan blok muka lebar 0,68m, tinggi 1,36 m, jarak antar blok muka 1,69 m dan berjumlah 13 buah. Nilai kontrol stabilitas pada saat kondisi air normal adalah Stabilitas terhadap Guling S = 5,34 > 1,5 (Aman), Stabilitas terhadap geser S = 8,95 > 1,5 (Aman), Eksentrisitas yang terjadi di e = -7,37 < 1,16 (Aman), Daya dukung tanah ɑ min = 1,37 t/m2 < 20 t/m2 (Aman), Erosi bawah Tanah (piping) C = 4,57 ≥ 1,8 (Aman) dan kondisi air banjir adalah Stabilitas terhadap Guling S = 3,69 > 1,5 (Aman), Stabilitas terhadap geser S = 4.12 > 1,5 (Aman), Eksentrisitas yang terjadi di e = -12,05 < 1,16 (Aman), Daya dukung tanah ɑ min = -0.5 t/m2 < 20 t/m2 (Aman), Erosi bawah Tanah (piping) C = 3,22 ≥ 1,8 (Aman). Nilai keamanan yang diperoleh dapat dinyatakan aman sehingga desain kolam peredam energi pada bendung memenuhi syarat. Kata kunci : Bilangan Froude, Kolam Peredam Energi, Bendung v DESAIN KOLAM PEREDAM ENERGI BENDUNG PLAOSAN KABUPATEN SEMARANG Program Studi Teknik Sipil, Fakultas Teknik, Universitas Undaris Jalan Tentara Pelajar No.13 Ungaran, Kabupaten Semarang. 50514, ABSTRACT The hydraulic aspect of the weir is one of the most important factors in the design of the energy absorber pool. The remaining energy downstream of the energy absorber pond is expected to be minimal so that scouring the riverbed is not dangerous. Currently, the Plaosan Dam does not yet have an energy absorber pool structure. Therefore, it is necessary to recommend a pond design to anticipate scouring. The analysis carried out includes hydrological analysis, including calculating the annual planned rainfall, planned flood discharge (Q) using the Haspers method, and calculating the Froude number (Fr) to determine the appropriate type of pond. Then obtained recommendations for the design of the type of energy absorber pool and also carried out a stability analysis that works on the building. From the results of the calculation of the planned rainfall, the rainfall plan for the 50 year return period is 108.68 mm. The 50-year plan discharge is 186.06 m3/s, froude number = 4. The appropriate type of energy absorber pool is USBR Type IV. The pool is planned to have a length of 17 m L, with a front block of 0.68 m wide, 1.36 m high, a distance between blocks of 1.69 m and a total of 13 units. The stability control values under normal water conditions are Stability to Roll S = 5,34 > 1.5 (Safe), Stability to shear S = 8.94 > 1.5 (Safe), Eccentricity that occurs at e = -7, 37 < 1.16 (Safe), Soil bearing capacity min = 1,37 t/m2 < 20 t/m2 (Safe), Underground erosion (piping) C = 4.57 ≥ 1.8 (Safe) and condition flood water is Stability to Roll S = 3.69 > 1.5 (Safe), Stability to shear S = 4.12 > 1.5 (Safe), Eccentricity that occurs at e = -12,05 < 1.16 (Safe) , Soil bearing capacity min = 1,37 t/m2 < 20 t/m2 (Safe), Underground erosion (piping) C = -0,50 ≥ 1.8 (Safe). The safety value obtained can be declared safe so that the design of the energy absorber pool on the weir meets the requirements. Keywords : Froude Number, Energy Damping Pool, Weir

Item Type: Thesis (Masters)
Subjects: T Technology > TA Engineering (General). Civil engineering (General)
Divisions: Fakultas Teknik > S1 Teknik Sipil
Depositing User: LIBRARY UNDARIS -
Date Deposited: 20 Dec 2022 03:43
Last Modified: 20 Dec 2022 03:43
URI: http://repository.undaris.ac.id/id/eprint/759

Actions (login required)

View Item View Item